PX3-1066 - Raritan Unit Metered iPDU: Single Phase, 230V AC, 32A, 24 Outlets: 24x Schuko (CEE 7/4), Input: IEC 60309 32A, 7.4kVA, Zero U Vertical, 2x USB-A, 1x USB-B, Replaceable LCD Color Display, Ethernet and Sensor Connections (PX-1000 Series) BTO
Description:
The Raritan PX-1000 family of high-quality rack power distribution units (PDUs) offers real-time remote unit-level power monitoring of current (amps), voltage, power (kVA, kW), power factor and energy consumption (kWh) with ISO/IEC +/- 1% billing-grade accuracy. The PX-1000 also supports Raritan’s plug-and- lay environmental sensors. Users can define thresholds and receive alerts when thresholds are crossed for both power and environmental events.
The PX-1000 1U (horizontal mount) form with a wide variety of IEC. Precise power information can be monitored, and the PX-1000 configured, via a user-friendly Web browser GUI or command line interface. Power information is also displayed at the PDU locally. Security is ensured with up to 256-bit encryption, strong passwords and advanced authorization options, including permissions, LDAP/S and Active Directory. Plus the PX-1000 series is fully compatible with Raritan's Power IQ energy management software solutions.
Features:
Energy Metering Voltage (V), Current (A), Active Power (kW), Real Power (kVA), Energy (kWh), Power Factor
Metering Accuracy ISO/IEC 62053-21 1%
Metering per Input Line Yes
Metering per Branch Circuit Breaker Yes
Metering per Output Receptacle No
Remote Outlet Switching No
Environmental Sensor Ready Yes
Networking 10/100 BaseT Ethernet. Optional WiFi (802.11a/b/g/n)
Remote Management HTTP(s); SSH; Telnet; RS-232 (Serial); Power IQ; SNMP version v2/v3; SMTP; JSON-RPC
Cascading Yes
Max 8 PDUs can be daisy chained using a single Ethernet connection
Onboard Display User-selectable display (voltage, current, or active power:per line, per breaker, or per receptacle)
Compatible Sensors: Temperature, Humidity, Air Flow, Static Pressure, Single cable connection provides temp/humidity monitoring at three points in cabinet (with a single sensor assembly)
Replaceable controller
Power Metering and Monitoring
Remote power monitoring, metering and rich data collection including current (amps), voltage, power (kVA, kW) and energy consumption (kWh) Make informed capacity planning decisions and efficiently utilise power resources such as finding stranded power in racks. Measure IT equipment power consumption to save power and money, calculate Green Grid’s PUE Level 2 and Level 3, and drive green data centre initiatives.
LED and alarms for unbalanced loads based on user-adjustable thresholds Increase efficiency, utilization and capacity. Load balance lines and circuits to avoid overloading neutral lines. Improve uptime and staff productivity.
Capable of ISO/IEC +/- 1% billing-grade accuracy real-time power monitoring and metering, down to individual outlets for some models Report and/or bill back power consumption (kWh). Trend and track energy utilization or bill power costs to users.
User-adjustable power data sampling and buffering End users can choose the frequency at which they monitor power and the amount of data they gather.
Power Management, Security and Remote Access
Alerts via SNMP, e-mail and syslog from individual outlets, units, lines and circuit breakers when user-adjustable thresholds are exceeded Receive advanced warning of potential problems with critical and non-critical thresholds and alerts.
Standards based polling, configuration and alerting with encryption via SNMP v1, v2, v3 support, SETs, GETs and TRAPs Increase uptime with alerts. Collect data for trending and capacity management.
Ethernet, serial, USB-A, USB-B and sensor connections Supports modem control functions for serial console access. Connectivity options for third-party peripherals enabling new applications, e.g., wireless, USB drives, etc.
Directory services support providing advanced authorization options, including permissions, LDAP/S, RADIUS and Active Directory®. 256-bit AES encryption and strong passwords Configure user access rights and security settings.
Remote access via Web and CLI. Supports HTTP, HTTPS, SSH and Telnet Check status of PDUs, lines, circuit breakers and individual outlets. For switched models, remotely provision (turn on), reboot and switch individual outlets and groups of outlets with user-configurable, outlet-level delays for power sequencing.
Compatible with Raritan’s Power IQ® Centralize power control and analytics and measure CO2 footprints.
Environmental Monitoring
Environment-monitoring-ready intelligent rack PDUs with optional plug-and-play environmental sensors
Monitor temperature and humidity to identify hot spots, confidently raise the ambient temperature of your data center to reduce cooling power consumption and manage static problems. Increase efficiency with ASHRAE guidelines.
Alerts based on user-defined environmental thresholds Save costs by leveraging PX to monitor the data center environment and receive alerts when thresholds are reached.
LED indication if sensor is plugged in and detected Provides confidence that environmental sensors are functioning and properly monitoring the data center environment.
Hardware
Hundreds of models Meets all your data center applications, including models with outlet switching and individual outlet metering.
High-power, including 400V power distribution and high temp 60C models For high-heat environments such as blade servers, high-density applications and storage area networks (SANs). Supports hot aisle containment and high-power blade racks.
High-quality construction and components such as solder connections to copper bus bars in PCBs, ISO 9000 quality manufacturing and quality components from Tyco, Hubbell® and Mennekes® Superior reliability compared to other rack PDUs available.
Lightweight and strong extruded aluminum chassis with excellent heat dissipation and versatile button and bracket mounts Mounting flexibility.
Designed with 3D CAD/CAM software Up to 36% less deep than competitive products for easier rack mounting and minimal equipment and airflow blocking.
UL489 circuit breakers Meets Underwriters Laboratories’ latest branch circuit protection standards. Unlike fuses, an electrician or an inventory of spare fuses are not required. Eliminates the possibility of installing a fuse with the wrong rating.
Smart reversible LED display that changes orientation Easily check power readings, such as line draw and balance for three-phase rack PDUs at the rack before adding devices. Increases installation flexibility.
Raritan’s 25 years of data centre management and embedded development experience led to the embedded high-performance processor Rich and full implementation network management, directory services and security with best-in-class user experience.
Scalability and headroom for future upgrades.
PLUG: IEC60309 32A (Single Phase)
Specification:
PX3-1066 - Raritan Unit Metered iPDU: Single Phase, 230V AC, 32A, 24 Outlets: 24x Schuko (CEE 7/4), Input: IEC 60309 32A, 7.4kVA, Zero U Vertical, 2x USB-A, 1x USB-B, Replaceable LCD Color Display, Ethernet and Sensor Connections (PX-1000 Series)
BTO - (BUILT TO ORDER)
INPUT
Input Plug IEC 60309 2P+E 6h 32A 2P3W (L1/N/E)
IP44("splashproof") (230V, Single phase)
Cord Length 3 meters (9.84 feet) standard
Cord Entry Bottom-front feed
Cable Type 2P 3W
Number of Power Cords 1
Maximum Input Current 32A (per line)
Nominal Input Voltage 230V, Single phase
Rated Input Voltage 200 - 240V, Single phase
Input Frequency 50/60Hz
Power Capacity 6.4kVA at 200V, 7.7kVA at 240V
OUTPUT
Nominal Output Voltage 230V
Rated Output Voltage 200 - 240V
Output Connections (24) CEE 7/4; 16A
Overload Protection (2) 16A 1-pole LEGBXA6-16 circuit breaker
Cable Retention Optional retention clips are also available
PHYSICAL
Unit Dimensions (W x D x H) 2.1" x 2.6" x 73.1" ; 52mm x 65mm x 1856mm
Shipping Dimensions (W x D x H) 11.02" x 4.53" x 78.35" ; 280mm x 115mm x 1990mm
Colour Black powder coat
Mounting G2-RACK-FOR-ZU
ENVIRONMENTAL
Operating Environment 5 - 60°C (41 - 140°F)
Operating Relative Humidity 5-85%
Operating Elevation 0-10000ft
CONFORMANCE
Regulatory Approvals CE, Canada ICES-003, Class A Part 15 Class A of the FCC rules RoHS